Electroencephalographic recordings were acquired with a Neuroscan NuAmp system (Neuroscan Laboratories, El Paso, Tex). The electroencephalogram was recorded from the scalp through 34 sintered silver/silver chloride electrodes using an electrode cap (EasyCap; Falk Minow Services, Herrsching-Breitbrunn, Germany). The following 34 equidistant electrode positions were used: Fp1, Fp2, Fz, F3, F4, F7, F8, FC1, FC2, FC5, FC6, Cz, C3, C4, CP1, CP2, CP5, CP6, Pz, P3, P4, P7, P8, O1, O2, PO9, PO10, Iz, T1, T2, T7, T8, TP9, and TP10 (Figure 1). Electrodes placed at the tip of the nose and at Fpz served as the reference and ground, respectively. Four additional electrodes placed above and below the left eye and at the outer canthi of both eyes were used for monitoring blinks and eye movements. All impedances were kept below 4 kΩ. Signals were digitized at a rate of 1 kHz, with system acquisition filter settings at 0.5 to 100 Hz. Electroencephalography and stimulus markers were recorded continuously. During testing, online ERP averages to standard and deviant tones were also acquired to monitor signal quality and track the number of sweeps free of gross artifact (±100 μV across the −100 to 500 milliseconds following stimuli). Electroencephalographic acquisition was terminated when a minimum of 225 artifact-free deviant trials were collected. No subject required presentation of more than 300 deviant tones to obtain 225 artifact-free epochs during acquisition. Data processing was performed off-line and blind to group membership using automated procedures. First, continuous recordings were mathematically corrected for eye movement artifact using established methods.80 Continuous data were divided into epochs relative to the onset of stimuli (−100 to 500 milliseconds), and centered at the mean of the prestimulus baseline. Following blink correction, epochs containing greater than ±50 μV in frontal recording sites (F7, F8, Fp1, Fp2, F3, F4, and Fz) were automatically rejected.62 Event-related potential waveforms were generated for the responses to standard and deviant tones (Figure 1). On average, schizophrenia patients and healthy comparison subjects had 247 and 255 artifact-free deviant trials, respectively, following off-line processing. Mismatch negativity waveforms were generated by subtracting ERP waveforms in response to standard tones from the ERPs generated in response to the deviant tones (Figure 2). The resultant MMN subtraction waveforms were low-pass filtered at 20 Hz (0-phase shift and 24-dB/octave roll-off) to remove any residual high-frequency artifact.62 The MMN amplitude was measured as the mean voltage from 135 to 205 milliseconds.67